Covers thermal rating models (CIGRE TB 601, IEEE 738), conductor physics, and electrical properties for overhead transmission lines. Use when implementing thermal calculations, validating conductors, or computing sag and resistance. Not for infrastructure deployment (use infrastructure-management) or system architecture.
Resources
1Install
npx skillscat add levifig/loaf/dist-codex-skills-power-systems-modeling Install via the SkillsCat registry.
Power Systems Reference
Contents
- Critical Rules
- Verification
- Quick Reference
- Topics
- Available Scripts
- Default Standard
- Unit Conventions
- Standard Citations
- Testing Tolerances
- Related Skills
Follows loaf-core code quality and TDD principles.
Domain knowledge for overhead transmission line physics, thermal ratings, and mechanical analysis.
Critical Rules
- Always validate physical parameters at function boundaries; raise
ValueErrorfor out-of-range values - Use CIGRE TB 601 as the default thermal rating standard; document deviations in code comments
- Always cite standard section numbers in code comments (e.g.,
CIGRE TB 601, Section 4.2.3) - Use SI units internally (temperatures in Kelvin); convert to Celsius only for display
- Use
pytest.approx()withrel=1e-3for thermal calculation tolerances
Verification
- Confirm all physical parameters are validated against bounds before computation
- Verify standard citations are present in code comments for thermal formulas
- Run
loaf check boundsto check parameter values against physical limits
Quick Reference
| Parameter | Valid Range |
|---|---|
| Conductor temperature | -40°C to 250°C |
| Ambient temperature | -50°C to 60°C |
| Wind speed | 0 to 50 m/s |
| Solar radiation | 0 to 1400 W/m² |
Topics
| Topic | Reference | Use When |
|---|---|---|
| Thermal Models | references/thermal-models.md | CIGRE TB 601, IEEE 738 thermal rating implementations |
| Conductor Limits | references/conductor-limits.md | Physical validation bounds and parameter constraints |
| Electrical Properties | references/electrical-properties.md | Resistance, sag, catenary formulas and calculations |
| Standards Reference | references/standards-reference.md | Industry standards summary (CIGRE, IEEE, IEC, EN) |
Available Checks
| Check | Usage | Description |
|---|---|---|
| Bounds | loaf check bounds -t conductor_temp -v 85 |
Validate physics values against bounds. --unit K converts temperature first. |
| Units | loaf check units 25 C K |
Convert between units (temp, length, power, speed) |
| Standard refs | loaf check standard-refs [dir] |
Check for CIGRE/IEEE citations and section numbers in Python files |
Default Standard
CIGRE TB 601 is the default thermal rating standard. Document any deviations in code comments. IEEE 738 differs in treatment of low wind speeds.
Unit Conventions
- Internal: SI units, temperatures in Kelvin
- Display: Celsius for temperatures
- Document: Always include units in variable names or docstrings
Standard Citations
Always cite standard section numbers in code comments:
# CIGRE TB 601, Section 4.2.3: Natural convection heat loss
# Formula: P_n = pi * D * lambda * Nu * (T_s - T_a)Testing Tolerances
Thermal calculations: use pytest.approx() with rel=1e-3 (0.1% accuracy).
Related Skills
database-design— For persisting physics results- loaf-core/code-style — For Python conventions in physics code